Multi-functional System
From traditional panoramic exams to endodontics, implant planning and oral surgery applications, the CS 8200 3D is capable of far more than the average 3D unit.
Optional cephalometric configuration available
Award-winning 2D technology delivers superb panoramic images in seconds
Accurate 3D representations ensure optimal diagnostic results
CAD/CAM abilities: scan models and impressions
Empowers you to perform more procedures in your practice
Extended Field of View
Optimal for single and dual arches scan including third-molars
Single scan with no stitchingAvoid taking multiple scans and unneccessary patient exposures
Ideal for multiple implant surgeries, surgical guide fabrication, third-molar assessment
CS MAR
Metal Artefact Reduction is an extended licence option for both the CS8200 3D & Existing CS8100 3D
- Features a unique live comparison tool
- Enables live comparison of images with and without MAR filter
- Helps confirm diagnoses and reduces risk of misinterpretation
Advanced Noise Reduction System
- Improves perception of cortical bone edge, ligament space, soft tissues and small details (ie. lateral canal, crack…)
- Ideal for 75 microns resolution scan
Low Dose Imaging
3D IMAGES AT A LOWER DOSE THAN 2D PANORAMIC
Up to an 83% lower radiation dose than 2D panoramic imaging
- Covers multiple applications:
- Implant planning
- Follow-up exams
- Pediatric examinations
- Impactions/supernumerary evaluations
Implants
Implant planning using CS 3D Imaging (12 cm x10 cm)
Control of bone grafting (12 cm x 5 cm)
ENDO HD MODE
- Voxel size 75 µm
- Ideal for endodontics and any case requiring the highest resolution possible
- Available on 4 cm x 4 cm and 5 cm x 5 cm FOV
STANDARD RESOLUTION MODE
- Voxel size 150 µm or 300 µm
- For most indications requiring high quality images and shorter exposure times
LOW DOSE MODE
- Voxel size 400 µm
- The lowest effective dose
- For sensitive cases requiring low dose, such as pediatric or follow up examinations
Implants
Implant planning using CS 3D Imaging (12 cm x10 cm)
Control of bone grafting (12 cm x 5 cm)
Implants
Follow up of implant placement using metal artifact reduction (12 cm x 5 cm)
Endodontics
External cervical resorption (5 cm x 5 cm)
Failing root canal treatment (5 cm x 5 cm)
Vertical radicular fracture (5 cm x 5 cm)
Periodontics / Fractures
Cyst assessment (12 cm x 5 cm)
Root fracture (8 cm x 9 cm)
Periodontal condition (12 cm x 10 cm)
Orthodontics
Impacted canine (12 cm x 10 cm)
Third molar assessment (12 cm x 10 cm)